Home Liquid level indicators and regulators Level indicators and regulators:

- Regulator - level indicator

RSU-41Н - Regulator - level indicator

Choose a modification:

Order code:

RSU-41Н
AA
Availability of RS-485 interface:

Number:

Available for order.

The RSU-41 device provides control of the level of liquid or bulk materials in the tank.

Functional capabilities:

  • Control of the level of liquid and bulk materials using four sensors.
  • Connection of a wide range of level sensors (conductometric, float, contactless switches, etc.).
  • Operation in the tank filling and emptying mode.
  • Manual or automatic mode of control of the electric drive of the actuator (pump, conveyor, solenoid valve, etc.).
  • Alarm of emergency overflow or drainage of the tank.
  • Work with liquids that differ in electrical conductivity: tap water, contaminated water, milk and food products.
Inputs:
  • quantity: 4
  • independent
  • 10V(10Hz).
Виходи:
  • quantity: 4
  • Relay
  • 250V, 8A.
Interface:
  • option
  • RS-485
  • Modbus RTU
Seller

from

5 076

including VAT

Choose a modification and complete your order code

RSU-31

RSU-41Н

Input signals:

Number of level control channels:

3

4

Types of sensors that can be connected:

кондуктометричні
float
mechanical contact devices

кондуктометричні
float
mechanical contact devices

Діапазон чутливості:

from 0 kOhm to 1.7 kOhm
from 1.7 kOhm to 17 kOhm
from 17 kOhm to 170 kOhm
from 170 kOhm to 1.7 MOhm

from 0 kOhm to 1.7 kOhm
from 1.7 kOhm to 17 kOhm
from 17 kOhm to 170 kOhm
from 170 kOhm to 1.7 MOhm

Supply voltage of level sensors:

10 V (10 Hz)

10 V (10 Hz)

Output signals:

Quantity outputs:

3

4

Output type:

switching relay
no more than: 250V, 8А

switching relay
no more than: 250V, 8А

Interfaces:

Data exchange interface:

RS-485

RS-485

Data exchange protocol:

Modbus RTU

Modbus RTU

Electrical data:

Supply voltage:

230 V

230 V

Power consumption:

4 VA

4 VA

Galvanic isolation:

• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 1500 V.

• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 1500 V.

Corps:

Installation type:

on DIN rail
on the wall (optional)

on DIN rail

Case size (HxWxD):

145х120х80 mm

106х90х58 mm

Weight, not more than:

0.7 kg

0.7 kg

Degree of protection:

IP65

IP65

Operating conditions:

Ambient temperature:

-40 °C to +70 °C

-40 °C to +70 °C