Touch operator panels Weintek
I/O modules
Spark protection barrier
Recorders and archivers
Meters and converters of electrical network parameters
Counters, timers, tachometers
Liquid level indicators and regulators
Programmed logical controllers
Manual signal transmitters
Technological signaling devices
Power supplies
Codesys PLC controllers
Galvanic isolation and branching blocks
Communication interface converters and amplifiers
Analytical instruments
Switching blocks
Control and protection units
GSM communication routers / modems
Dual-channel microprocessor PID controller
МІК-322-К7
МІК-122
МІК-122Н
МІК-22
Regulation type:
ON/OFF
Three-position
Analog PID controller
Pulse PID controller
PWM PID controller
Synchronous PID control of two circuits
ON/OFF
Three-position
Analog PID controller
Pulse PID controller
PWM PID controller
ON/OFF
Three-position
Analog PID controller
Pulse PID controller
PWM PID controller
ON/OFF
Three-position
Analog PID controller
Pulse PID controller
Number of independent regulators:
2
2
2
2
Additional features:
Auto-tuning
Signaller
Converter
Mathematical functions
Signaller
Converter
Signaller
Converter
Signaller
Converter
Feedback
Quantity of analog inputs:
2
2
2
2
Output type:
unified: passive
thermal resistance: three-wire connection
unified: passive
thermal resistance: three-wire connection
unified: passive
thermal resistance: three-wire connection
unified: passive
thermal resistance: three-wire connection
Types of input sensors and signals:
0-5 mA, 0-20 mA, 4-20 mA, -5-5 mA, -20-20 mA
0-10 V, 0-100 mV, -10-10 V, -100-100 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,N,J,S,R,B,T,E,A-1, A-2, A-3, A, C
0-150 Ohm, 0-300 Ohm, 0-1200 Ohm, 0-2500 Ohm
0-5 mA, 0-20 mA, 4-20 mA
0-2 V, 0-10 V, 0-75 mV, 0-200 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,J,S,B,T,A-1
0-1000 Ohm
0-5 mA, 0-20 mA, 4-20 mA
0-2 V, 0-10 V, 0-75 mV, 0-200 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100
Type: K,L,J,S,B,T,A-1
0-5 mA, 0-20 mA, 4-20 mA
0-2 V, 0-10 V, 0-75 mV, 0-200 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,J,S,B,T,A-1
0-1000 Ohm
Limit of the basic combined measurement error:
≤ 0.2
≤ 0.4 % (when switching to another sensor type, without calibration)
≤ 0.2
≤ 0.2
≤ 0.2
Рolling cycle time:
up to 0.1
up to 0.1
up to 0.1
up to 0.1
Galvanic isolation:
• Input isolated from other circuits.
• Input isolated from other circuits.
• Input isolated from other circuits.
• Input isolated from other circuits.
Switching to another sensor type:
User-selectable sensor type switching. No calibration required.
User-configurable, calibration required
User-configurable, calibration required
User-configurable, calibration required
Quantity of discrete inputs:
2
2
2
2
Trigger signal levels:
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state 18-30 V
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state: 18-30 V
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state 18-30 V
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state 18-30 V
Input consumption:
≤ 10 mА
≤ 10 mА
≤ 10 mА
≤ 10 mА
Number of outputs:
2 (option)
2
2
1
Output type:
active
active
active
active
Ranges of possible output signals:
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
The limit of the main combined error of the output signal formation:
≤ 0.2 %
≤ 0.2 %
≤ 0.2 %
≤ 0.2 %
Quantity of discrete outputs:
up to 6
4
4
4
Types of discrete outputs:
• NPN transistor: up to 40V, 100mA
• Closing relays: up to 230V, 5A (subject to ordering 4P)
• Switching relay: up to 230V, 8A (up to 2)
• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• Opto-symistor: up to 300V, 0.7A
• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• NPN transistor: up to 40V, 100mA (КБЗ-25-11)
• Switching relay: up to 230V, 8A (КБЗ-28Р-11)
• Opto-symistor: up to 300V, 0.7A (КБЗ-28С-11)
• Solid state relay: up to 60V, 1.0AAC/ADC (КБЗ-28К-11)
Data exchange interface:
RS-485
USB
RS-485
RS-485
RS-485
Data exchange protocol:
Modbus RTU
Modbus RTU
Modbus RTU
Modbus RTU
Indication type:
Seven-segment, digital
Seven-segment, digital
Seven-segment, digital
Seven-segment, digital
Indication accuracy:
Four categories
Four categories
Four categories
Four categories
Supply voltage:
Alternating current: 230 V
Direct current: 24 V
Alternating current: 230 V
Direct current: 24 V
Alternating current: 230 V
Direct current: 24 V
Alternating current: 230 V
Direct current: 24 V
Power consumption:
Alternating current: no more than 7.0 VA
Direct current: no more than 350 mA
Alternating current: no more than 8.3 VA
Direct current: no more than 350 mA
Alternating current: no more than 7.0 VA
Direct current: no more than 250 mA
Alternating current: no more than 8.5 VA
Direct current: no more than 250 mA
Availability of a built-in power supply for inputs:
Yes, optional, if specified in the order
= 24 V, 25 mА
Yes, optional, if specified in the order
= 24 V, 25 mА
Yes, optional, if specified in the order
= 24 V, 25 mА
Yes, optional, if specified in the order
= 24 V, 25 mА
Non-volatile memory:
Yes, EEPROM
Yes, EEPROM
Yes, EEPROM
Yes, EEPROM
Galvanic isolation:
• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V
• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V
• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V
• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V
Installation type:
Shield
Shield
DIN-rail
Shield
Case size (HxWxD):
96х96х135 mm
96х96х135 mm
110х160х58 mm
96х96х135 mm
Weight, not more than:
no more than 0.6 kg
no more than 0.35 kg
no more than 0.5 kg
no more than 0.35 kg
Degree of protection:
IP30
IP30
IP30
IP30
Ambient temperature:
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C