Home Meters and converters of electrical network parameters Electrical meters and indicators:

- AC Voltage Indicator-Converter

ІПМ-2 - AC Voltage Indicator-Converter

Choose a modification:

Order code:

ІПМ-2
AA
Input signal range:
BB
Analog output signal type:
CC
Discrete output signal type:
R
RS-485 interface presence:
U
Power Supply Voltage:

Number:

Available for order.

The IPM-2N indicator-converter is designed for measuring and displaying AC voltage signals, with the ability to convert the measured value into a standardized analog DC current signal or control a single discrete output with alarm functionality. An RS-485 interface with Modbus RTU protocol is provided to enable integration into SCADA systems or HMI panels. Modern alternative to traditional pointer-type AC voltmeters.

Functions:

  • Measurement of AC voltage signals;
  • Input signal filtering and scaling;
  • Front panel display of the measured input value;
  • Linear conversion of the input signal into a standardized analog output signal: 0–5 mA, 0–20 mA, 4–20 mA, 0–10 V;
  • Alarm signaling for deviations from user-defined setpoints;
  • Complete galvanic isolation.
Input signal:
  • single-phase
  • AC voltage (modifications)
Analog output (optional):
  • quantity: 1
  • 0..5 mА, 0..20 mА, 4..20 mА
  • 0..10 V
Discrete output (optional):
  • quantity: 1
  • NPN transistor
  • Relay
Interfaces:
  • RS-485 (optional)
  • Modbus RTU protocol
Assembling:
  • on DIN rail
  • 100х55х60 mm.
Power supply:
  • = 24 V, 110 mA
  • ~230 V, 2.5 VA
Seller

from

5 004

including VAT

Choose a modification and complete your order code

ІПМ-2

ІПМ-2

General information:

Type of power supply:

Single-phase

Single-phase

Input signal type:

AC voltage

AC voltage

Input signals:

Quantity inputs:

1

1

Ranges of possible input signals:

From 1 to 10 V / R = 50 kΩ
From 1.5 to 15 V / R = 75  kΩ
From 3 to 30 V / R = 100  kΩ
From 4 to 40 V / R = 150  kΩ
From 5 to 50 V / R = 200  kΩ
From 6 to 60 V / R = 250  kΩ
From 10 до 100 V / R = 500  kΩ
From 25 до 250 V / R = 1.2 MΩ
From 30 до 300 V / R = 2 MkΩ
From 50 до 500 V / R = 2.5 MΩ

From 1 to 10 V / R = 50 kΩ
From 1.5 to 15 V / R = 75  kΩ
From 3 to 30 V / R = 100  kΩ
From 4 to 40 V / R = 150  kΩ
From 5 to 50 V / R = 200  kΩ
From 6 to 60 V / R = 250  kΩ
From 10 до 100 V / R = 500  kΩ
From 25 до 250 V / R = 1.2 MΩ
From 30 до 300 V / R = 2 MkΩ
From 50 до 500 V / R = 2.5 MΩ

Limit of the basic combined measurement error:

0,4 %

0,4 %

Measurement and conversion period:

0.1 seconds

0.1 seconds

Ultimate load:

Repeated twice, duration up to 5 seconds

Repeated twice, duration up to 5 seconds

Analog output signals:

Number of outputs:

1 (optional)

1 (optional)

Output type:

Active output

Active output

Ranges of possible output signals:

0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ

0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ

Discrete output signals:

Quantity of discrete outputs:

1 (optional)

1 (optional)

Types of discrete outputs:

• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A

• NPN transistor: up to 40V, 100mA
• Closing relay: up to 230V, 5A

Interfaces:

Data exchange interface:

RS-485

RS-485

Data exchange protocol:

Modbus RTU

Modbus RTU

Indication:

Digital display:

Seven-segment

Seven-segment

Electrical data:

Supply voltage:

Alternating current: 230 V

Direct current: 24 V
Alternating current: 230 V

Power consumption:

Alternating current: ≤ 4.0 VА

Direct current: no more than 110 mА
Alternating current: ≤ 2.5 VА

Non-volatile memory:

Yes, EEPROM

Yes, EEPROM

Galvanic isolation:

• Full. All nodes are isolated from each other
• Galvanic (electrical) isolation voltage not less than 1500  V

• Full. All nodes are isolated from each other
• Galvanic (electrical) isolation voltage not less than 1500  V

Corps:

Installation type:

shield

for DIN rail mounting

Weight, not more than:

not more than 0.25 kg

not more than 0.15 kg

Case size (HxWxD):

48х96х106 mm

98х54х57 mm

Degree of protection:

IP30

IP20

Operating conditions:

Ambient temperature:

-40 °C to +70 °C

-40 °C to +70 °C