- AC Voltage Indicator-Converter
ІПМ-2
ІПМ-2
Type of power supply:
Single-phase
Single-phase
Input signal type:
AC voltage
AC voltage
Quantity inputs:
1
1
Ranges of possible input signals:
From 1 to 10 V / R = 50 kΩ
From 1.5 to 15 V / R = 75 kΩ
From 3 to 30 V / R = 100 kΩ
From 4 to 40 V / R = 150 kΩ
From 5 to 50 V / R = 200 kΩ
From 6 to 60 V / R = 250 kΩ
From 10 до 100 V / R = 500 kΩ
From 25 до 250 V / R = 1.2 MΩ
From 30 до 300 V / R = 2 MkΩ
From 50 до 500 V / R = 2.5 MΩ
From 1 to 10 V / R = 50 kΩ
From 1.5 to 15 V / R = 75 kΩ
From 3 to 30 V / R = 100 kΩ
From 4 to 40 V / R = 150 kΩ
From 5 to 50 V / R = 200 kΩ
From 6 to 60 V / R = 250 kΩ
From 10 до 100 V / R = 500 kΩ
From 25 до 250 V / R = 1.2 MΩ
From 30 до 300 V / R = 2 MkΩ
From 50 до 500 V / R = 2.5 MΩ
Limit of the basic combined measurement error:
0,4 %
0,4 %
Measurement and conversion period:
0.1 seconds
0.1 seconds
Ultimate load:
Repeated twice, duration up to 5 seconds
Repeated twice, duration up to 5 seconds
Number of outputs:
1 (optional)
1 (optional)
Output type:
Active output
Active output
Ranges of possible output signals:
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
Quantity of discrete outputs:
1 (optional)
1 (optional)
Types of discrete outputs:
• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• NPN transistor: up to 40V, 100mA
• Closing relay: up to 230V, 5A
Data exchange interface:
RS-485
RS-485
Data exchange protocol:
Modbus RTU
Modbus RTU
Digital display:
Seven-segment
Seven-segment
Supply voltage:
Alternating current: 230 V
Direct current: 24 V
Alternating current: 230 V
Power consumption:
Alternating current: ≤ 4.0 VА
Direct current: no more than 110 mА
Alternating current: ≤ 2.5 VА
Non-volatile memory:
Yes, EEPROM
Yes, EEPROM
Galvanic isolation:
• Full. All nodes are isolated from each other
• Galvanic (electrical) isolation voltage not less than 1500 V
• Full. All nodes are isolated from each other
• Galvanic (electrical) isolation voltage not less than 1500 V
Installation type:
shield
for DIN rail mounting
Weight, not more than:
not more than 0.25 kg
not more than 0.15 kg
Case size (HxWxD):
48х96х106 mm
98х54х57 mm
Degree of protection:
IP30
IP20
Ambient temperature:
-40 °C to +70 °C
-40 °C to +70 °C