Touch operator panels Weintek
I/O modules
Spark protection barrier
Recorders and archivers
Meters and converters of electrical network parameters
Counters, timers, tachometers
Liquid level indicators and regulators
Programmed logical controllers
Manual signal transmitters
Technological signaling devices
Power supplies
Codesys PLC controllers
Galvanic isolation and branching blocks
Communication interface converters and amplifiers
Analytical instruments
Switching blocks
Control and protection units
GSM communication routers / modems
МР-51Н-11
МР-51Н-13
МР-51Н-15
Quantity of analog outputs:
1
1
1
Types of analog output signals:
0-5 mА , 0(4)-20 mА, 0-10V
0-5 mА , 0(4)-20 mА, 0-10V
0-5 mА , 0(4)-20 mА, 0-10V
The limit of the main combined error of the output signal formation:
±0,4 %
±0,4 %
±0,4 %
Galvanic isolation:
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
Quantity of discrete inputs:
16
8
-
Trigger signal levels:
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state: 18-30 V
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state: 18-30 V
-
Input consumption:
≤ 10 mA
≤ 10 mA
-
Galvanic isolation:
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
-
Quantity of discrete outputs:
Not included
8
16
Output types:
Not included
• Closing relay: up to 220V, 5A
• Closing relay: up to 220V, 5A
Galvanic isolation:
Not included
• Full. The input is isolated from other circuits.
• Full. The input is isolated from other circuits.
Installation type:
on DIN rail
on DIN rail
on DIN rail
Case size (HxWxD):
110x160x58
110x160x58
110x160x58
Weight, not more than:
1.0 kg
1.0 kg
1.0 kg
Degree of protection:
IP30
IP30
IP30
Supply voltage:
• Alternating current: ~ 230 (+22 V, -33 V) (50 ± 1) Hz
• Direct current: 24±4 V
• Alternating current: ~ 230 (+22 V, -33 V) (50 ± 1) Hz
• Direct current: 24±4 V
• Alternating current: ~ 230 (+22 V, -33 V) (50 ± 1) Hz
• Direct current: 24±4 V
Power consumption:
• Alternating current: 13 VA
• Direct current: no more than 350 mA
• Alternating current: 13 VA
• Direct current: no more than 350 mA
• Alternating current: 13 VA
• Direct current: no more than 350 mA
Ambient temperature:
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C
Premises of use:
closed explosion-proof, fire-proof
closed explosion-proof, fire-proof
closed explosion-proof, fire-proof
Vibration:
with a frequency of up to 60 Hz with an amplitude of up to 0.1 mm
with a frequency of up to 60 Hz with an amplitude of up to 0.1 mm
with a frequency of up to 60 Hz with an amplitude of up to 0.1 mm
Atmospheric pressure:
from 84 to 106.7 kPa
from 84 to 106.7 kPa
from 84 to 106.7 kPa