Home Normalizing converters Pneumatic:

- Pneumatic-electric transducer, absolute and relative

PEP-420 - Pneumatic-electric transducer, absolute and relative

Choose a modification:

Order code:

PEP-420
AA
Input signal range:
PP
Type of measuring pressure:
TT
Size of the tube to be connected:

Number:

Available for order.

Pneumatic-electric signal conversion unit, with galvanic isolation:

  • Designed for continuous proportional conversion of the signal: excess pressure of compressed air coming from pneumatic devices of pressure, vacuum, pressure difference, level and density of liquid, into a current signal of 4...20 mA and power supply: current loop.
  • Input signal measurement range: 0 - 10 kPa; 0 - 50 kPa; 0 - 100 kPa; 20 - 100 kPa; 0 - 200 kPa.
  • Power supply: current loop;
  • Screw terminal block.
Inputs:
  • quantity: 1
  • 0-10kPa, 0-50kPa, 0-100kPa, 20-100kPa, 0-200kPa.
Inlet pressure type:
  • absolute
  • relative
Outputs:
  • quantity: 1
  • 4-20mA
  • current loop
Seller

from

11 142

including VAT

Choose a modification and complete your order code

PEP-11

PEP-420

PEP-420

Input signals:

Quantity inputs:

1

1

1

Input type:

Absolute pressure
Gage pressure
Differential pressure

Differential pressure

Absolute pressure
Differential pressure

Ranges of possible input signals:

0 - 10 kPа
0 - 50 kPa
0 - 100 kPa
20 - 100 kPa
0 - 200 kPa

0 - 10 kPа
0 - 50 kPa
0 - 100 kPa
20 - 100 kPa
0 - 200 kPa

0 - 10 kPа
0 - 50 kPa
0 - 100 kPa
20 - 100 kPa
0 - 200 kPa

Limit of the basic combined measurement error:

0-10 kPа: ±1,0 %
0-50 kPа: ±0,5 %
0-200 kPа: ±0,5 %
0-100 kPa ±0,25 %
20-100 kPa ±0,25 %

0-10 kPа: ±1,0 %
0-50 kPа: ±0,5 %
0-200 kPа: ±0,5 %
0-100 kPa ±0,25 %
20-100 kPa ±0,25 %

0-10 kPа: ±1,0 %
0-50 kPа: ±0,5 %
0-200 kPа: ±0,5 %
0-100 kPa ±0,25 %
20-100 kPa ±0,25 %

Measurement and conversion period:

0,01 second

0,01 second

0,01 second

Analog output signals:

Number of outputs:

1

1

1

Output type:

active

passive, current loop

passive, current loop

Ranges of possible output signals:

0 to 5 mA / R = 2000 Ohm
0 to 20 mA / R ≤ 500 Ohm
4 to 20 mA / R ≤ 500 Ohm
0 to 10 V / R ≥ 2000 Ohm

4 to 20 mA / R ≤ 500 Ohm

4 to 20 mA / R ≤ 500 Ohm

Discrete output signals:

Availability of discrete outputs:

No

No

No

Quantity of discrete outputs:

not included

not included

not included

Types of discrete outputs:

not included

not included

not included

Interfaces:

Data exchange interface:

not included

not included

not included

Data exchange protocol:

not included

not included

not included

Indication:

Digital display:

No

No

No

Electrical data:

Supply voltage:

Direct current: 24 V
Alternating current: 230 V

Current loop, 24V

Current loop, 24V

Power consumption:

Direct current: no more than 120 mA
Alternating current: no more than 5 VA

no more than 20 mA (channel)

no more than 20 mA (channel)

Non-volatile memory:

not included

not included

not included

Galvanic isolation:

• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 500 V.

• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 500 V.

• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 500 V.

Corps:

Installation type:

on DIN rail

on DIN rail

on DIN rail

Case size (HxWxD):

96х55х110 mm

76х26х115 mm

76х26х115 mm

Weight, not more than:

0,4 kg

0,2 kg

0,2 kg

Degree of protection:

IP30

IP30

IP30

Operating conditions:

Ambient temperature:

-40 °C to +70 °C

-40 °C to +70 °C

-40 °C to +70 °C