QNT-1 is a high-precision microprocessor-based device designed for receiving, processing, and displaying signals from incremental encoders or other pulse sensors, with the capability to generate discrete control signals for external equipment.

🎯 Purpose:

The counter provides:

  • 📡 Measurement of an input physical parameter (rotation angle, linear displacement, number of revolutions) from an incremental encoder.
  • 🧮 Mathematical processing of input data (counting, scaling, filtering) with subsequent display of the current value on the built-in digital indicator.
  • ⚡ Generation of discrete output signals for controlling actuators according to user settings.

🚀 Key Features and Functional Capabilities

🔄 Two operating modes:

  • 📐 Quadrature counter – operates with two counting inputs (DI1, DI2), determining the counting direction based on the phase shift between the signals.
  • 🎛 Command counter – operates with one counting input and a separate command input to set the counting direction.

🔌 Universal inputs:

  • Supports connection of PNP/NPN-type sensors, dry contacts, high- and low-level sensors, and incremental encoders.
  • 🛡 Galvanic isolation of the inputs ensures protection against industrial interference.

🌐 Data communication interfaces:

  • RS-485 with Modbus RTU protocol support for integration into automated process control systems (APCS).
  • USB port for direct PC connection and parameter configuration.

💡 Two discrete outputs (DO1, DO2):

Programmable setpoints SET POINT 1 and SET POINT 2 for output activation.

Capability to control loads: ⚙️ switching mechanisms on/off, 📢 signaling, ⏱ generating pulses of a specified duration.

Inputs:
  • 4
  • PNP/NPN type
  • =24V
Outputs:
  • quantity: 2
  • transistor OK: up to 40V, 100mA
  • switching relay: up to 230V, 8A
  • solid-state relay: up to 40V, 0.5A
Interfaces:
  • USB (configuration)
  • RS-485
  • Modbus RTU protocol.
Counting modes:
  • Quadrature
  • Сommand
Assembling:
  • on DIN rail
  • 100х55х60 mm.
Power supply:
  • = 24 V, 65mA
  • ~230V, 1.5VA
Seller

from

4 530

including VAT

Choose a modification and complete your order code

QNT-1

QNT-11

Modes:

Operating modes:

Encoder, counter

Encoder, counter

Number of counters:

one

one

Discrete input signals:

Quantity of discrete inputs:

4

4

Maximum pulse frequency:

100 kHz

100 kHz

Minimum input pulse duration:

5 µs

5 µs

Input current (input consumption), no more:

5 mA

5 mA

Trigger signal levels:

Logical "0" signal – "DISABLED" state: 0-5V
Сигнал логічної "1" – стан "УВІМКНЕНО": 18-30V

Logical "0" signal – "DISABLED" state: 0-5V
Сигнал логічної "1" – стан "УВІМКНЕНО": 18-30V

Connectable sensors:

• Encoders

• Encoders

Discrete output signals:

Quantity of discrete outputs:

2

2

Output types:

• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• Solid-state (non-mechanical) relay: 40 V, up to 0.5 A (AC/DC)

• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• Solid-state (non-mechanical) relay: 40 V, up to 0.5 A (AC/DC)

Load type:

Active
Inductive

Active
Inductive

Indication:

Indication type:

OLED display, 1.8"

Seven-segment
8th digit

Interfaces:

Data exchange interface:

USB
RS-485

USB
RS-485

Data exchange protocol:

Modbus RTU

Modbus RTU

Electrical data:

Supply voltage:

Direct current: 24 V
Alternating current: 230 V

Direct current: 24 V
Alternating current: 230 V

Power consumption:

Direct current: no more than 60 mA
Alternating current: no more than 1.5VA

Direct current: no more than 120 mA
Alternating current: no more than 2.7VA

Availability of a built-in power supply for inputs:

Yes, (option when ordering)
=24V, 30mA

Yes, (option when ordering)
=24V, 30mA

Galvanic isolation:

• Combined. Inputs have group isolation. Outputs, interface and power are isolated from other nodes and from each other.
• Galvanic isolation voltage is not less than 500 V.

• Combined. Inputs have group isolation. Outputs, interface and power are isolated from other nodes and from each other.
• Galvanic isolation voltage is not less than 500 V.

Corps:

Installation type:

on DIN rail

shield

Case size (HxWxD):

100х55х60 mm

48х96х106 mm

Weight, not more than:

0,35 kg

0,35 kg

Degree of protection:

IP20

IP20

Operating conditions:

Ambient temperature:

-40 °C to +70 °C

-40 °C to +70 °C