Touch operator panels Weintek
I/O modules
Spark protection barrier
Recorders and archivers
Meters and converters of electrical network parameters
Counters, timers, tachometers
Liquid level indicators and regulators
Programmed logical controllers
Manual signal transmitters
Technological signaling devices
Power supplies
Codesys PLC controllers
Galvanic isolation and branching blocks
Communication interface converters and amplifiers
Analytical instruments
Switching blocks
Control and protection units
GSM communication routers / modems
QNT-1
QNT-11
Operating modes:
Encoder, counter
Encoder, counter
Number of counters:
one
one
Quantity of discrete inputs:
4
4
Maximum pulse frequency:
100 kHz
100 kHz
Minimum input pulse duration:
5 µs
5 µs
Input current (input consumption), no more:
5 mA
5 mA
Trigger signal levels:
Logical "0" signal – "DISABLED" state: 0-5V
Сигнал логічної "1" – стан "УВІМКНЕНО": 18-30V
Logical "0" signal – "DISABLED" state: 0-5V
Сигнал логічної "1" – стан "УВІМКНЕНО": 18-30V
Connectable sensors:
• Encoders
• Encoders
Quantity of discrete outputs:
2
2
Output types:
• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• Solid-state (non-mechanical) relay: 40 V, up to 0.5 A (AC/DC)
• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• Solid-state (non-mechanical) relay: 40 V, up to 0.5 A (AC/DC)
Load type:
Active
Inductive
Active
Inductive
Indication type:
OLED display, 1.8"
Seven-segment
8th digit
Data exchange interface:
USB
RS-485
USB
RS-485
Data exchange protocol:
Modbus RTU
Modbus RTU
Supply voltage:
Direct current: 24 V
Alternating current: 230 V
Direct current: 24 V
Alternating current: 230 V
Power consumption:
Direct current: no more than 60 mA
Alternating current: no more than 1.5VA
Direct current: no more than 120 mA
Alternating current: no more than 2.7VA
Availability of a built-in power supply for inputs:
Yes, (option when ordering)
=24V, 30mA
Yes, (option when ordering)
=24V, 30mA
Galvanic isolation:
• Combined. Inputs have group isolation. Outputs, interface and power are isolated from other nodes and from each other.
• Galvanic isolation voltage is not less than 500 V.
• Combined. Inputs have group isolation. Outputs, interface and power are isolated from other nodes and from each other.
• Galvanic isolation voltage is not less than 500 V.
Installation type:
on DIN rail
shield
Case size (HxWxD):
100х55х60 mm
48х96х106 mm
Weight, not more than:
0,35 kg
0,35 kg
Degree of protection:
IP20
IP20
Ambient temperature:
-40 °C to +70 °C
-40 °C to +70 °C