МІК-112
МІК-121
МІК-121Н
МІК-121Т
МІК-21
МІК-25
Regulation type:
ON/OFF
Three-position
Analog PID controller
Pulse PID controller
PWM PID controller
Cascade regulator
PID ratio controller
PID controller with correction
ON/OFF
Three-position
Analog PID controller
Pulse PID controller
PWM PID controller
Cascade regulator
PID ratio controller
PID controller with correction
ON/OFF
Three-position
Analog PID controller
Pulse PID controller
PWM PID controller
Cascade regulator
PID ratio controller
PID controller with correction
ON/OFF
Three-position
Analog PID controller
Pulse PID controller
PWM PID controller
Cascade regulator
PID ratio controller
PID controller with correction
ON/OFF
Three-position
Analog PID controller
Pulse PID controller
PWM PID controller
PID ratio controller
PID controller with correction
ON/OFF
Three-position
Analog PID controller
Pulse PID controller
PWM PID controller
Cascade regulator
PID ratio controller
PID controller with correction
Number of independent regulators:
1
1
1
1
1
1
Additional features:
Signaller
Converter
Feedback
Signaller
Converter
Feedback
Signaller
Converter
Feedback
Signaller
Converter
Feedback
Signaller
Converter
Feedback
Signaller
Converter
Feedback
Quantity of analog inputs:
2
2
2
2
2
2
Output type:
unified: passive
thermal resistance: three-wire connection
unified: passive
thermal resistance: three-wire connection
unified: passive
thermal resistance: three-wire connection
unified: passive
thermal resistance: three-wire connection
unified: passive
thermal resistance: three-wire connection
unified: passive
thermal resistance: three-wire connection
Types of input sensors and signals:
0-5 mA, 0-20 mA, 4-20 mA
0-2 V, 0-10 V, 0-75 mV, 0-200 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100
Type: K,L,J,S,B,T,A-1
0-5 mA, 0-20 mA, 4-20 mA
0-2 V, 0-10 V, 0-75 mV, 0-200 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,J,S,B,T,A-1
0-1000 Ohm
0-5 mA, 0-20 mA, 4-20 mA
0-2 V, 0-10 V, 0-75 mV, 0-200 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100
Type: K,L,J,S,B,T,A-1
0-5 mA, 0-20 mA, 4-20 mA
0-2 V, 0-10 V, 0-75 mV, 0-200 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,J,S,B,T,A-1
0-1000 Ohm
NTC (0-1 kΩ, 0-3 kΩ, 0-5 kΩ, 0-10 kΩ)
0-5 mA, 0-20 mA, 4-20 mA
0-2 V, 0-10 V, 0-75 mV, 0-200 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,J,S,B,T,A-1
0-1000 Ohm
0-5 mA, 0-20 mA, 4-20 mA
0-2 V, 0-10 V, 0-75 mV, 0-200 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,J,S,B,T,A-1
0-1000 Ohm
Limit of the basic combined measurement error:
≤ 0.2
≤ 0.2
≤ 0.2
≤ 0.2
≤ 0.2
≤ 0.2
Рolling cycle time:
up to 0.1
up to 0.1
up to 0.1
up to 0.1
up to 0.1
up to 0.1
Galvanic isolation:
• Input isolated from other circuits.
• Input isolated from other circuits.
• Input isolated from other circuits.
• Input isolated from other circuits.
• Input isolated from other circuits.
• Input isolated from other circuits.
Switching to another sensor type:
User-configurable, calibration required
User-configurable, calibration required
User-configurable, calibration required
User-configurable, calibration required
User-configurable, calibration required
User-configurable, calibration required
Quantity of discrete inputs:
Not included
2
2
2
2
2
Trigger signal levels:
Not included
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state 18-30 V
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state 18-30 V
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state 18-30 V
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state 18-30 V
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state 18-30 V
Input consumption:
Not included
≤ 10 mА
≤ 10 mА
≤ 10 mА
≤ 10 mА
≤ 10 mА
Number of outputs:
1
1
1
1
1
1
Output type:
active
active
active
active
active
active
Ranges of possible output signals:
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
The limit of the main combined error of the output signal formation:
≤ 0.2 %
≤ 0.2 %
≤ 0.2 %
≤ 0.2 %
≤ 0.2 %
≤ 0.2 %
Quantity of discrete outputs:
2
4
4
4
4
4
Types of discrete outputs:
• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• Opto-symistor: up to 300V, 0.7A
• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• NPN transistor: up to 40V, 100mA
• Closing relays: up to 230V, 5A
• NPN transistor: up to 40V, 100mA (КБЗ-25-11)
• Switching relay: up to 230V, 8A (КБЗ-28Р-11)
• Opto-symistor: up to 300V, 0.7A (КБЗ-28С-11)
• Solid state relay: up to 60V, 1.0AAC/ADC (КБЗ-28К-11)
• NPN transistor: up to 40V, 100mA (КБЗ-25-11)
• Switching relay: up to 230V, 8A (КБЗ-28Р-11)
• Opto-symistor: up to 300V, 0.7A (КБЗ-28С-11)
• Solid state relay: up to 60V, 1.0AAC/ADC (КБЗ-28К-11)
Data exchange interface:
RS-485
RS-485
RS-485
RS-485
RS-485
RS-485
Data exchange protocol:
Modbus RTU
Modbus RTU
Modbus RTU
Modbus RTU
Modbus RTU
Modbus RTU
Indication type:
Seven-segment, digital
Seven-segment, digital
Seven-segment, digital
Seven-segment, digital
Seven-segment, digital
Seven-segment, digital
Indication accuracy:
Four categories
Four categories
Four categories
Four categories
Four categories
Four categories
Supply voltage:
Alternating current: 230 V
Direct current: 24 V
Alternating current: 230 V
Direct current: 24 V
Alternating current: 230 V
Direct current: 24 V
Alternating current: 230 V
Direct current: 24 V
Alternating current: 230 V
Direct current: 24 V
Alternating current: 230 V
Direct current: 24 V
Power consumption:
Alternating current: no more than 6.5 VA
Direct current: no more than 180 mA
Alternating current: no more than 6.5 VA
Direct current: no more than 180 mA
Alternating current: no more than 7.0 VA
Direct current: no more than 250 mA
Alternating current: no more than 3.6 VA
Direct current: no more than 150 mA
Alternating current: no more than 8.5 VA
Direct current: no more than 250 mA
Alternating current: no more than 8.5 VA
Direct current: no more than 250 mA
Availability of a built-in power supply for inputs:
Yes, optional, if specified in the order
= 24 V, 25 mА
Yes, optional, if specified in the order
= 24 V, 25 mА
Yes, optional, if specified in the order
= 24 V, 25 mА
Yes, optional, if specified in the order
= 24 V, 25 mА
Yes, optional, if specified in the order
= 24 V, 25 mА
Yes, optional, if specified in the order
= 24 V, 25 mА
Non-volatile memory:
Yes, EEPROM
Yes, EEPROM
Yes, EEPROM
Yes, EEPROM
Yes, EEPROM
Yes, EEPROM
Galvanic isolation:
• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V
• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V
• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V
• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V
• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V
• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V
Installation type:
Shield
Shield
DIN-rail
DIN rail
Wall mounting
Shield
Shield
Case size (HxWxD):
48х96х162 mm
96х96х135 mm
110х160х58 mm
145х120х80 mm
96х96х135 mm
96х96х135 mm
Weight, not more than:
no more than 0.35 kg
no more than 0.35 kg
no more than 0.35 kg
no more than 0.35 kg
no more than 0.35 kg
no more than 0.35 kg
Degree of protection:
IP30
IP30
IP30
IP30
IP30
IP30
Ambient temperature:
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C