Home Meters-indicators Single-channel meters-indicators:

Indicator - measuring device for technological parameters

ІТМ-300 Indicator - measuring device for technological parameters

Choose a modification:

Order code:

ІТМ-300
AA
Input Signal Type:
C
Type of the first control output signal:
D
Discrete Output Signal Code:
U
Power Supply Voltage:

Number:

Available for order.

ITM-300А is an industrial single-channel indicator - a meter designed to measure temperature, pressure, humidity, flow, level and other physical quantities in various industries (depending on the sensors that are connected).

Functional capabilities:

  • measurement of temperature or other physical quantities (pressure, humidity, flow, level, etc.) using sensors with a unified output signal of current or voltage;
  • digital filtering and correction of the input signal;
  • scaling of the scale of each input;
  • alarm function when the measured parameter goes beyond the specified range, with activation of discrete outputs;
  • linear conversion of the input signal into an output analog signal of a unified type;
  • indication of the measured value on a 6-digit, 7-segment display;
  • the possibility of inclusion in the dispatching system and data transmission to the upper level via the RS-485 interface.
Input signals:
  • quantity: 1
  • unified signals
  • voltage
  • resistance temperature transducers
  • thermocouples
Analog output:
  • quantity: 1
  • unified signals
Discrete outputs:
  • quantity: 2
  • transistor OK: up to 40V, 100mA
  • relay: up to 230V, 5A.
Interfaces:
  • RS-485
  • Modbus RTU protocol
Power supply:
  • ~ 100 V to ~ 242 V, 4 VA
  • = 18 V to 36 V, 200 mА
Assembling:
  • panel
  • 48x96x106 mm
Seller

from

4 968

including VAT

Choose a modification and complete your order code

ІТМ-310

ІТМ-310A

ІТМ-311

ІТМ-311В

ІТМ-300

ІТМ-300

General information:

Device type:

Technological indicator

Technological indicator

Technological indicator

Technological indicator

Technological indicator

Technological indicator

Additional features:

Input signal conversion
Alarms
Integration

Input signal conversion
Alarms
Integration

Input signal conversion
Alarms
Integration

Input signal conversion
Alarms
Integration

Input signal conversion
Alarms
Integration

Input signal conversion
Alarms
Integration

Analog input signals:

Quantity of analog inputs:

1

1

1

1

1

1

Types of input sensors and signals:

0-5 mA, 0-20 mA, 4-20 mA, -5-5 mA, -20-20 mA
0-10 V, 0-100 mV, -10-10 V, -100-100 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,N,J,S,R,B,T,E,A-1, A-2, A-3
0-150 Ohm, 0-300 Ohm, 0-1200 Ohm, 0-2500 Ohm
NTC (0-1 kΩ, 0-3 kΩ, 0-5 kΩ, 0-10 kΩ)

0-5 mA, 0-20 mA, 4-20 mA, -5-5 mA, -20-20 mA
0-10 V, 0-100 mV, -10-10 V, -100-100 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,N,J,S,R,B,T,E,A-1, A-2, A-3
0-150 Ohm, 0-300 Ohm, 0-1200 Ohm, 0-2500 Ohm
NTC (0-1 kΩ, 0-3 kΩ, 0-5 kΩ, 0-10 kΩ)

0-5 mA, 0-20 mA, 4-20 mA, -5-5 mA, -20-20 mA
0-10 V, 0-100 mV, -10-10 V, -100-100 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,N,J,S,R,B,T,E,A-1, A-2, A-3
0-150 Ohm, 0-300 Ohm, 0-1200 Ohm, 0-2500 Ohm
NTC (0-1 kΩ, 0-3 kΩ, 0-5 kΩ, 0-10 kΩ)

0-5 mA, 0-20 mA, 4-20 mA, -5-5 mA, -20-20 mA
0-10 V, 0-100 mV, -10-10 V, -100-100 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,N,J,S,R,B,T,E,A-1, A-2, A-3
0-150 Ohm, 0-300 Ohm, 0-1200 Ohm, 0-2500 Ohm
NTC (0-1 kΩ, 0-3 kΩ, 0-5 kΩ, 0-10 kΩ)

0-5 mA, 0-20 mA, 4-20 mA, -5-5 mA, -20-20 mA
0-10 V, 0-100 mV, -10-10 V, -100-100 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,N,J,S,R,B,T,E,A-1, A-2, A-3
0-150 Ohm, 0-300 Ohm, 0-1200 Ohm, 0-2500 Ohm
NTC (0-1 kΩ, 0-3 kΩ, 0-5 kΩ, 0-10 kΩ)

0-5 mA, 0-20 mA, 4-20 mA, -5-5 mA, -20-20 mA
0-10 V, 0-100 mV, -10-10 V, -100-100 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,N,J,S,R,B,T,E,A-1, A-2, A-3
0-150 Ohm, 0-300 Ohm, 0-1200 Ohm, 0-2500 Ohm
NTC (0-1 kΩ, 0-3 kΩ, 0-5 kΩ, 0-10 kΩ)

Limit of the basic combined measurement error:

≤ 0.2 %
≤ 0.4 % (when switching to another sensor type, without calibration)

≤ 0.1 %
≤ 0.4 % (when switching to another sensor type, without calibration)

≤ 0.2 %
≤ 0.4 % (when switching to another sensor type, without calibration)

≤ 0.2 %
≤ 0.4 % (when switching to another sensor type, without calibration)

≤ 0.2 %
≤ 0.4 % (when switching to another sensor type, without calibration)

≤ 0.1 %
≤ 0.4 % (when switching to another sensor type, without calibration)

Рolling cycle time:

up to 0.1 seconds

up to 0.1 seconds

up to 0.1 seconds

up to 0.1 seconds

up to 0.1 seconds

up to 0.1 seconds

Galvanic isolation:

• Input isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.

• Input isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.

• Input isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.

• Input isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.

• Not available

• Not available

Switching to another sensor type:

User-selectable sensor type switching. No calibration required.

User-selectable sensor type switching. No calibration required.

User-selectable sensor type switching. No calibration required.

User-selectable sensor type switching. No calibration required.

User-selectable sensor type switching. No calibration required.

User-selectable sensor type switching. No calibration required.

Discrete input signals:

Quantity of discrete inputs:

1

1

1

1

Not available

Not available

Trigger signal levels:

• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state 18-30 V

• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state 18-30 V

• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state 18-30 V

• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state 18-30 V

Not available

Not available

Input consumption:

≤ 10 mА

≤ 10 mА

≤ 10 mА

≤ 10 mА

Not available

Not available

Analog output signals:

Number of outputs:

1 (option)

1 (option)

1 (option)

1 (option)

1 (option)

1 (option)

Output type:

active

active

active

active

active

active

Ranges of possible output signals:

0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ

0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ

0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ

0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ

0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ

0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ

The limit of the main combined error of the output signal formation:

≤ 0.2 %

≤ 0.2 %

≤ 0.2 %

≤ 0.2 %

≤ 0.2 %

≤ 0.2 %

Discrete output signals:

Quantity of discrete outputs:

2 (optional)
4 (optional)

2 (optional)
4 (optional)

2 (optional)
4 (optional)

2 (optional)
4 (optional)

2 (optional)

2 (optional)

Types of discrete outputs:

• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A (subject to order 2P)
• Closing relays: up to 230V, 5A (subject to ordering 4P)

• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A (subject to order 2P)
• Closing relays: up to 230V, 5A (subject to ordering 4P)

• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A (subject to order 2P)
• Closing relays: up to 230V, 5A (subject to ordering 4P)

• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A (subject to order 2P)
• Closing relays: up to 230V, 5A (subject to ordering 4P)

• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• Closing relays: up to 230V, 5A

• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• Closing relays: up to 230V, 5A

Interfaces:

Data exchange interface:

RS-485
USB

RS-485
USB

RS-485
USB

RS-485
USB

RS-485

RS-485

Data exchange protocol:

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

Modbus RTU

Indication:

Indication type:

Seven-segment, digital

Seven-segment, digital

Seven-segment, digital
Linear indicator, bar graph

Seven-segment, digital
Linear indicator, bar graph

Seven-segment, digital

Seven-segment, digital

Indication accuracy:

Four categories

6-digit display

Four categories

Four categories

Four categories

Six digits

Electrical data:

Supply voltage:

Alternating current: 230 V
Direct current: 24 V

Alternating current: 230 V
Direct current: 24 V

Alternating current: 230 V
Direct current: 24 V

Alternating current: 230 V
Direct current: 24 V

Alternating current: 230 V
Direct current: 24 V

Alternating current: 230 V
Direct current: 24 V

Power consumption:

Direct current: no more than 200 mA
Alternating current: no more than 4 VA

Direct current: no more than 200 mA
Alternating current: no more than 4 VA

Direct current: no more than 250 mA
Alternating current: no more than 4 VA

Direct current: no more than 250 mA
Alternating current: no more than 4 VA

Direct current: no more than 200 mA
Alternating current: no more than 4 VA

Direct current: no more than 200 mA
Alternating current: no more than 4 VA

Availability of a built-in power supply for inputs:

Yes, optional, if specified in the order
= 24 V, 25 mА

Yes, optional, if specified in the order
= 24 V, 25 mА

Yes, optional, if specified in the order
= 24 V, 25 mА

Yes, optional, if specified in the order
= 24 V, 25 mА

Not available

Not available

Non-volatile memory:

Yes, EEPROM

Yes, EEPROM

Yes, EEPROM

Yes, EEPROM

Yes, EEPROM

Yes, EEPROM

Galvanic isolation:

• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V

• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V

• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V

• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V

• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V

• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V

Corps:

Installation type:

Shield

Shield

Shield

Shield

Shield

Shield

Case size (HxWxD):

48х96х106 mm

48х96х106 mm

48х96х106 mm

96х48х106 mm

48х96х106 mm

48х96х106 mm

Weight, not more than:

не більше 0,25 kg

не більше 0,25 kg

не більше 0,25 kg

не більше 0,25 kg

не більше 0,25 kg

не більше 0,25 kg

Degree of protection:

IP30

IP30

IP30

IP30

IP30

IP30

Operating conditions:

Ambient temperature:

-40 °C to +70 °C

-40 °C to +70 °C

-40 °C to +70 °C

-40 °C to +70 °C

-40 °C to +70 °C

-40 °C to +70 °C