- DC current and voltage converter
ПНС-1
ПНС-101
ПНС-650
ПНС-651
ПНС-410
Type of power supply:
Single-phase
Single-phase
Single-phase
Single-phase
Single-phase
Input signal type:
DC voltage
DC current
DC voltage
DC current
DC voltage
DC current
DC voltage
DC current
Quantity inputs:
1
1
1
1
1
Ranges of possible input signals:
From 0 (–75) to 75 mV (from shunt) / R = 250 kΩ
From 0 (–10) to 10 V / R = 130 kΩ
From 0 (–15) to 15 V / R = 200 kΩ
From 0 (–60) to 60 V / R = 267 kΩ
From 0 (–100) to 100 V / R = 200 kΩ
From 0 (–150) to 150 V / R = 667 kΩ
From 0 (–250) to 250 V / R = 667 kΩ
From 0 (–500) to 500 V / R = 1.3 MΩ
From 0 (–750) to 750 V / R = 15 Ω
From 0 (–5) to 5 mA / R = 15 Ω
From 0 (–20) to 20 mA / R = 3,75 Ω
From 4 to 20 mA / R = 3,75 Ω
From 0 (–75) to 75 mV (from shunt) / R = 250 kΩ
From 0 (–10) to 10 V / R = 130 kΩ
From 0 (–15) to 15 V / R = 200 kΩ
From 0 (–60) to 60 V / R = 267 kΩ
From 0 (–100) to 100 V / R = 200 kΩ
From 0 (–150) to 150 V / R = 667 kΩ
From 0 (–250) to 250 V / R = 667 kΩ
From 0 (–500) to 500 V / R = 1.3 MΩ
From 0 (-750) to 750 V / R = 15 Ω
From 0 (–5) to 5 mA / R = 15 Ω
From 0 (–20) to 20 mA / R = 3,75 Ω
From 4 to 20 mA / R = 3,75 Ω
From 0 to 75 mV (from shunt) / R = 250 kΩ
From 0 to 10 V / R = 1 MΩ
From 0 to 15 V / R = 1.5 MΩ
From 0 to 60 V / R = 1.3 MΩ
From 0 to 100 V / R = 1.6 MΩ
From 0 to 150 V / R = 1.4 MΩ
From 0 to 250 V / R = 2.3 MΩ
From 0 to 500 V / R = 2.5 МΩ
From 75 to 75 mV (from shunt) / R = 250 kΩ
From -1 to 5 V / R = 1 MΩ
From -5 to 5 V / R = 1 MΩ
From -10 to 10 V / R = 1 MΩ
From 0 to 5 mA / R = 200 Ω
From 0 to 20 mA / R = 50 Ω
From 4 to 20 mA / R = 62 Ω
From 0 to 1A / R = 0.1 Ω
From 0 to 75 mV (from shunt) / R = 250 kΩ
From 0 to 10 V / R = 130 kΩ
From 0 to 15 V / R = 200 kΩ
From 0 to 60 V / R = 267 kΩ
From 0 to 100 V / R = 200 kΩ
From 0 to 150 V / R = 667 kΩ
From 0 to 250 V / R = 667 kΩ
From 0 to 500 V / R = 1 МΩ
From 0 to 5 mA / R = 200 Ω
From 0 to 20 mA / R = 50 Ω
From 4 to 20 mA / R = 62 MΩ
Limit of the basic combined measurement error:
0,25 %
0,2 %
0,2 %
0,2 %
0,25 %
Measurement and conversion period:
adjustable time: 0.5–6 seconds
no more 6 seconds
0.5 seconds
no more 6 seconds
Configurable: max 0.6 seconds
Ultimate load:
Repeated twice, duration up to 5 seconds
Repeated twice, duration up to 5 seconds
Repeated twice, duration up to 2 seconds
Repeated twice, duration up to 5 seconds
• an overvoltage of 5 times the nominal value for up to 5 seconds, for voltage levels up to 100 V.
• an overvoltage of 2 times the nominal value for up to 5 seconds, for voltage levels above 100 V.
Number of outputs:
1
1
1
1
1
Output type:
Active output
Active output
Active output
Active output
passive output
Ranges of possible output signals:
0 to 5 mA / R ≤ 2000 Ω
–5 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
–10 to 10 V / R ≤ 2 кΩ
0 to 5 mA / R ≤ 2000 Ω
–5 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
-20 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 10 кΩ
–10 to 10 V / R ≤ 10 кΩ
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 10 кΩ
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 10 кΩ
4 to 20 mA / R ≤ 500 Ω
Digital display:
Not included
Not included
Not included
Not included
Not included
Supply voltage:
Direct current: 24 V
Alternating current: 230 V
Direct current: 24 V
Alternating current: 230 V
Direct current: 24 V
Direct current: 24 V
Direct current: 24 V (current loop)
Power consumption:
Direct current: no more than 120 mА
Alternating current: ≤ 5.0 VА
Direct current: no more than 100 mА
Alternating current: ≤ 5.0 VА
Direct current: no more than 30 mА
Direct current: no more than 30 mА
Direct current: no more than 30 mА
Galvanic isolation:
• Complete. All nodes are isolated from each other
• Galvanic (electrical) isolation voltage not less than 2000 V
• Complete. All nodes are isolated from each other
• Galvanic (electrical) isolation voltage not less than 2000 V
• Complete. All nodes are isolated from each other
• Galvanic (electrical) isolation voltage not less than 2000 V
• Complete. All nodes are isolated from each other
• Galvanic (electrical) isolation voltage not less than 2000 V
-
Installation type:
for DIN rail mounting
for DIN rail mounting
for DIN rail mounting
for DIN rail mounting
for DIN rail mounting
Weight, not more than:
not more than 0.5 kg
not more than 0.5 kg
not more than 0.1 kg
not more than 0.1 kg
not more than 0.1 kg
Case size (HxWxD):
95х100х110 mm
100х23х115 mm
94х7х64 mm
94х7х64 mm
76х26х115 mm
Degree of protection:
IP30
IP30
IP20
IP20
IP20
Ambient temperature:
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C