Touch operator panels Weintek
I/O modules
Spark protection barrier
Recorders and archivers
Meters and converters of electrical network parameters
Counters, timers, tachometers
Liquid level indicators and regulators
Programmed logical controllers
Manual signal transmitters
Technological signaling devices
Power supplies
Codesys PLC controllers
Galvanic isolation and branching blocks
Communication interface converters and amplifiers
Analytical instruments
Switching blocks
Control and protection units
GSM communication routers / modems
МІК-341-К6
Regulation type:
ON/OFF
Three-position
Analog PID controller
Pulse PID controller
PWM PID controller
Number of independent regulators:
1
Additional features:
Auto-tuning
Signaller
Converter
Step-by-step work program
Quantity of analog inputs:
1
Output type:
unified: passive
thermal resistance: three-wire connection
Types of input sensors and signals:
0-5 mA, 0-20 mA, 4-20 mA, -5-5 mA, -20-20 mA
0-10 V, 0-100 mV, -10-10 V, -100-100 mV
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,N,J,S,R,B,T,E,A-1, A-2, A-3
0-150 Ohm, 0-300 Ohm, 0-1200 Ohm, 0-2500 Ohm
Limit of the basic combined measurement error:
≤ 0.2
≤ 0.4 % (when switching to another sensor type, without calibration)
Рolling cycle time:
up to 0.1
Galvanic isolation:
• Input isolated from other circuits.
Switching to another sensor type:
User-selectable sensor type switching. No calibration required.
Quantity of discrete inputs:
3
Trigger signal levels:
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state 18-30 V
Input consumption:
≤ 10 mА
Number of outputs:
1 (option)
Output type:
active
Ranges of possible output signals:
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
SSR relay
The limit of the main combined error of the output signal formation:
≤ 0.2 %
Quantity of discrete outputs:
4
Types of discrete outputs:
• NPN transistor: up to 40V, 100mA
• Closing relays: up to 230V, 5A (subject to ordering 4P)
Data exchange interface:
RS-485
USB
Data exchange protocol:
Modbus RTU
Indication type:
Seven-segment, digital
Indication accuracy:
Four categories
Supply voltage:
Alternating current: 230 V
Direct current: 24 V
Power consumption:
Alternating current: no more than 8.5 VA
Direct current: no more than 250 mA
Availability of a built-in power supply for inputs:
Yes, optional, if specified in the order
= 24 V, 25 mА
Non-volatile memory:
Yes, EEPROM
Galvanic isolation:
• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 500 V
Installation type:
Shield
Case size (HxWxD):
96х96х63 mm
Weight, not more than:
no more than 0.5 kg
Degree of protection:
IP30
Ambient temperature:
-40 °C to +70 °C