Home Normalizing converters Temperature sensor signals, analog:

- Thermoresistance signal conversion unit, current loop power supply

BPO-430 - Thermoresistance signal conversion unit, current loop power supply

Choose a modification:

Order code:

BPO-430
D
Type of sensor to be connected:
С
Symbol for the nominal static characteristic of the conversion:
W
Nominal value of the W100 ratio of the input signal:
N
Initial value of the measured temperature:
K
Final value of the measured temperature:

Number:

Available for order.

Thermocouple signal conversion unit with galvanic isolation:

  • Designed to convert signals from resistance temperature transducers Сu 50M, Сu 100M, TSM 23 gr., Cu 50, Cu 100, TSP 50P, TSP 100P, TSP 21gr., Pt 50, Pt 100, into a current signal of 4...20 mA and power supply: current loop.
  • Connection of sensors, according to a three-wire circuit.
  • Ranges of measured temperatures -200...+200 °C for copper temperature transducers and -200...+850 °C for platinum temperature transducers (depending on the type of resistance temperature transducer used).
  • Screw terminal block.

 

Inputs:
  • quantity: 1
  • TSM, TSP, Pt
  • three-wire connection.
Outputs:
  • quantity: 1
  • current loop
  • 4-20mA.
Power supply:
  • = 24 V
  • current loop.
Seller

from

3 438

including VAT

Choose a modification and complete your order code

BPO-644

BPO-31

BPO-430

Input signals:

Quantity inputs:

1

1

1

Input type:

Three-wire connection:

Three-wire connection:

Three-wire connection:

Ranges of possible input signals:

Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt50, Pt100, Pt500, Pt1000

Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt50, Pt100

Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt50, Pt100

Limit of the basic combined measurement error:

± 0,25 %

± 0,25 %

± 0,2 %

Measurement and conversion period:

0,01 second

0,01 second

0,01 second

Analog output signals:

Number of outputs:

1

1

1

Output type:

active

active

passive, current loop

Ranges of possible output signals:

0 to 5 mA / R = 2000 Ohm
0 to 20 mA / R ≤ 500 Ohm
4 to 20 mA / R ≤ 500 Ohm
0 to 10 V / R ≥ 2000 Ohm

0 to 5 mA / R = 2000 Ohm
0 to 20 mA / R ≤ 500 Ohm
4 to 20 mA / R ≤ 500 Ohm
0 to 10 V / R ≥ 10000 Ohm

4 to 20 mA / R ≤ 500 Ohm

Discrete output signals:

Availability of discrete outputs:

No

No

No

Quantity of discrete outputs:

not included

not included

not included

Types of discrete outputs:

not included

not included

not included

Interfaces:

Data exchange interface:

not included

not included

not included

Data exchange protocol:

not included

not included

not included

Indication:

Digital display:

No

No

No

Electrical data:

Supply voltage:

Direct current: 24 V

Direct current: 24 V

Current loop, 24V

Power consumption:

Direct current: no more than 30 mA

Direct current: no more than 110 mA

no more than 20 mA (channel)

Non-volatile memory:

not included

not included

not included

Galvanic isolation:

• Missing

• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 500 V.

Missing.

Corps:

Installation type:

on DIN rail

on DIN rail

on DIN rail

Case size (HxWxD):

94х7х64 mm

76х26х115 mm

76х26х115 mm

Weight, not more than:

0,1 kg

0,1 kg

0,13 kg

Degree of protection:

IP20

IP20

IP20

Operating conditions:

Ambient temperature:

-40 °C to +70 °C

-40 °C to +70 °C

-40 °C to +70 °C