Home Meters-indicators Single-channel meters-indicators:

Indicator - measuring device for technological parameters, with bar graph

ІТМ-101 Indicator - measuring device for technological parameters, with bar graph

Choose a modification:

Order code:

ІТМ-101
AA
Input signal type:
BB
Output signal type:
G
Power supply for passive sensors 0(4)-20mA:

Number:

Available for order.

ITM-101 - industrial single-channel indicator - meter, designed for measuring temperature, pressure, humidity, flow, level and other physical quantities in various industries (depending on the sensor that is connected).

Functional capabilities:

  • measurement of temperature or other physical quantities (pressure, humidity, flow, level, etc.) using sensors with a unified output signal of current or voltage;
  • digital filtering and correction of the input signal;
  • scaling of the scale of each input;
  • alarm function when the measured parameter goes beyond the specified range, with activation of discrete outputs;
  • linear conversion of the input signal into an output analog signal of a unified type;
  • indication of the measured value on a 4-digit, 7-segment display and a linear indicator (bargraph) of horizontal type;
  • the possibility of inclusion in the dispatching system and data transmission to the upper level via the RS-485 interface.
Input signal:
  • quantity: 1
  • unified signals
  • voltage
  • resistance temperature transducers
  • thermocouples
Analog output:
  • quantity: 1
  • unified signals
Discrete output:
  • quantity: 1
  • transistor OK: up to 40V, 100mA
  • switching relay: up to 230V, 8A.
Interface:
  • RS-485
  • Modbus RTU protocol
Assembling:
  • panel
  • 48x96x106 mm
Power supply:
  • ~ 100 V to ~ 230 V, 4 VA
Seller

from

5 088

including VAT

Choose a modification and complete your order code

ІТМ-101

ІТМ-101В

ІТМ-110Н

General information:

Device type:

Technological indicator

Technological indicator

Technological indicator

Additional features:

Input signal conversion
Alarms

Input signal conversion
Alarms

Input signal conversion
Alarms

Analog input signals:

Quantity of analog inputs:

1

1

1

Types of input sensors and signals:

0-5 mA, 0-20 mA, 4-20 mA
0-50 mВ , 0-100 mВ , 0-1 V, 0-10 V
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,J,S,B,E,A-1
0-1 kΩ, NTC (0-1 kΩ, 0-3 kΩ, 0-5 kΩ, 0-10 kΩ)

0-5 mA, 0-20 mA, 4-20 mA
0-50 mВ , 0-100 mВ , 0-1 V, 0-10 V
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,J,S,B,E,A-1
0-1 kΩ, NTC (0-1 kΩ, 0-3 kΩ, 0-5 kΩ, 0-10 kΩ)

0-5 mA, 0-20 mA, 4-20 mA
0-75 mВ , 0-200 mВ , 0-2 V, 0-10 V
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100, Pt500, Pt1000
Type: K,L,J,S,B,E,A-1
0-1 kΩ, NTC (0-1 kΩ, 0-3 kΩ, 0-5 kΩ, 0-10 kΩ)

Limit of the basic combined measurement error:

≤ 0.2 %

≤ 0.2 %

≤ 0.2 %

Рolling cycle time:

up to 0.1 seconds

up to 0.1 seconds

up to 0.1 seconds

Galvanic isolation:

Missing

Missing

• Input isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.

Switching to another sensor type:

The sensor type is specified when ordering, switching to another type is not possible

The sensor type is specified when ordering, switching to another type is not possible

User-configurable, calibration required

Discrete input signals:

Quantity of discrete inputs:

Not included

Not included

Not included

Analog output signals:

Number of outputs:

1 (option)

1 (option)

1

Output type:

active

active

active

Ranges of possible output signals:

0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ

0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ

0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ

The limit of the main combined error of the output signal formation:

≤ 0.2 %

≤ 0.2 %

≤ 0.2 %

Discrete output signals:

Quantity of discrete outputs:

1 (optional)

1 (optional)

2

Types of discrete outputs:

• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A

• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A

• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• Solid State Relay (SSR): up to 60 V, 1 A

Interfaces:

Data exchange interface:

RS-485

RS-485

RS-485

Data exchange protocol:

Modbus RTU

Modbus RTU

Modbus RTU
Slave, master

Indication:

Indication type:

Seven-segment, digital
Linear indicator, bar graph

Seven-segment, digital
Linear indicator, bar graph

Seven-segment, digital

Indication accuracy:

Four categories

Four categories

Four categories

Electrical data:

Supply voltage:

Alternating current: 230 V

Alternating current: 230 V

Alternating current: 230 V
Direct current: 24 V

Power consumption:

Alternating current: ≤ 4.0 VА

Alternating current: ≤ 4.0 VА

Alternating current: ≤ 6.5 VА
Direct current: no more than 180 mA

Availability of a built-in power supply for inputs:

ption, provided that a 4..20mA signal is ordered
= 24 V, 25 mА

ption, provided that a 4..20mA signal is ordered
= 24 V, 25 mА

ption, provided that a 4..20mA signal is ordered
= 24 V, 25 mА

Non-volatile memory:

Yes, EEPROM

Yes, EEPROM

Yes, EEPROM

Galvanic isolation:

• None for input signal. Output and interface are isolated from each other and power.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 1500 V

• None for input signal. Output and interface are isolated from each other and power.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 1500 V

• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 1500 V

Corps:

Installation type:

Shield

Shield

DIN-rail

Case size (HxWxD):

48х96х106 mm

96х48х106 mm

94х106х58 mm

Weight, not more than:

не більше 0,25 kg

не більше 0,25 kg

не більше 0,35 kg

Degree of protection:

IP30

IP30

IP30

Operating conditions:

Ambient temperature:

-40 °C to +70 °C

-40 °C to +70 °C

-40 °C to +70 °C