Touch operator panels Weintek
I/O modules
Spark protection barrier
Recorders and archivers
Meters and converters of electrical network parameters
Counters, timers, tachometers
Liquid level indicators and regulators
Programmed logical controllers
Manual signal transmitters
Technological signaling devices
Power supplies
Codesys PLC controllers
Galvanic isolation and branching blocks
Communication interface converters and amplifiers
Analytical instruments
Switching blocks
Control and protection units
GSM communication routers / modems
RIO-DO8
RIO-DO16
RIO-5N-DO16
RIO-mini DO8
Quantity of discrete outputs:
8
16
16
8
Output types:
• NPN transistor: up to 40V, 100mA
• Mechanical relay:
- 6 closing relays: 230V, 5A
- 2 switching relays: up to 230V, 8A
• Solid-state (non-mechanical) relay: 40 V, up to 0.5 A (AC/DC)
• NPN transistor: up to 40V, 100mA
• Solid-state (non-mechanical) relay: 40 V, up to 0.5 A (AC/DC)
• NPN transistor: up to 40V, 100mA
• Mechanical relay: 230V, 5А
• Solid-state (non-mechanical) relay: 40 V, up to 0.5 A (AC/DC)
• NPN transistor: up to 40V, 100mA
• Mechanical relay: 230V, 5А (only for DO5-DO8)
• Solid-state (non-mechanical) relay: 40 V, up to 0.5 A (AC/DC)
Load type:
Active
Inductive
Active
Inductive
Active
Inductive
Active
Inductive
Data exchange interface:
RS-485
RS-485
RS-485
RS-485
USB
Data exchange protocol:
Modbus RTU
Modbus RTU
Modbus RTU
Modbus RTU
Supply voltage:
Direct current: 24 V
Direct current: 24 V
Direct current: 12 V
Direct current: 24 V
Alternating current: 230 V
Direct current: 24 V
Alternating current: 230 V
Power consumption:
Direct current: no more than 130 mA
Direct current: no more than 90 mA
Direct current: no more than: 290mA (for 12V), 145mA (for 24V)
Alternating current: no more than: 5.5 ВА
Direct current: no more than: 60mA
Alternating current: no more than: 1.5 ВА
Galvanic isolation:
• Outputs isolated from each other, from power supply and interface
• The interface is galvanically isolated from inputs and other circuits.
• Galvanic isolation voltage is not less than 500 V.
• 4 groups of 4 channels isolated from power and interface
• The interface is galvanically isolated from inputs and other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Outputs isolated from each other, from power supply and interface
• The interface is galvanically isolated from inputs and other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Outputs isolated from each other, from power supply and interface
• The interface is galvanically isolated from inputs and other circuits.
• Galvanic isolation voltage is not less than 500 V.
Installation type:
DIN rail
DIN rail
DIN rail
DIN rail
Case size (HxWxD):
117х23х129 mm
117х23х129 mm
117х23х129 mm
100х55х60 mm
Weight, not more than:
0,18 kg
0,18 kg
0,18 kg
0,35 kg
Degree of protection:
IP20
IP20
IP20
IP20
Ambient temperature:
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C