- Programmable logic controller
МІК-50-16
МІК-50-17
МІК-50-26
МІК-50-27
Expansion module:
Not supported
Not supported
Not supported
Not supported
Quantity of analog inputs:
4
4
8
8
Types of input sensors and signals:
0-5mА, 0(4)-20mА, 0-10V
0-50mВ, 0-200mВ, 0-1V
Pt(50P, 100P, gr21, Pt50, Pt100, Pt500, Pt1000), Cu(50, 100, гр.23)
Type L, Type K, Type S, Type B, Type A, Type J, Type E
0-5mА, 0(4)-20mА, 0-10V
0-50mВ, 0-200mВ, 0-1V
Pt(50P, 100P, gr21, Pt50, Pt100, Pt500, Pt1000), Cu(50, 100, гр.23)
Type L, Type K, Type S, Type B, Type A, Type J, Type E
0-5mА, 0(4)-20mА, 0-10V
0-5mА, 0(4)-20mА, 0-10V
Limit of the basic combined measurement error:
± 0,2 %
± 0,2 %
± 0,2 %
± 0,2 %
Рolling cycle time:
0.1 second
0.1 second
0.1 second
0.1 second
Galvanic isolation:
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Group. The output group is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Group. The output group is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
Quantity of analog outputs:
2
1
1
not included
Types of analog output signals:
0-5 mА , 0(4)-20 mА, 0-10V
0-5 mА , 0(4)-20 mА, 0-10V
0-5 mА , 0(4)-20 mА, 0-10V
not included
The limit of the main combined error of the output signal formation:
АО1: ±0,2 %
АО2: ±0,4 %
АО1: ±0,2 %
АО1: ±0,2 %
not included
Galvanic isolation:
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Full. The output is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
not included
Quantity of discrete inputs:
3
2
3
2
Trigger signal levels:
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state: 18-30 V
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state: 18-30 V
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state: 18-30 V
• Logical "0" signal - DISABLED state: 0-7 V
• Logical "1" signal - ON state: 18-30 V
Input consumption:
≤ 10 mA
≤ 10 mA
-
-
Galvanic isolation:
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
Quantity of discrete outputs:
5
4
5
4
Output types:
• Transistor OK: up to 40V, 100mA
• Closing relay: up to 220V, 5A
• Transistor OK: up to 40V, 100mA
• Switching relay (DO1, DO2): up to 220V, 8A
• Solid state relay (DO1 - DO4): up to 60V, 1.0AAC/ADC
• Closing relay (DO3, DO4): up to 220V, 5A
• Transistor OK: up to 40V, 100mA
• Closing relay: up to 220V, 5A
• Transistor OK: up to 40V, 100mA
• Switching relay (DO1, DO2): up to 220V, 8A
• Solid state relay (DO1 - DO4): up to 60V, 1.0AAC/ADC
• Closing relay (DO3, DO4): up to 220V, 5A
Galvanic isolation:
• Group. The output group is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Full. The output is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Group. The output group is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
Indication type:
Seven-segment, four-digit
Seven-segment, four-digit
Seven-segment, four-digit
Seven-segment, four-digit
Indication accuracy:
± 0,01 %
± 0,01 %
± 0,01 %
± 0,01 %
Interface type:
RS-485
RS-485
RS-485
RS-485
Data exchange protocol:
Modbus-RTU (Slave mode)
Modbus-RTU (Slave mode)
Modbus-RTU (Slave mode)
Modbus-RTU (Slave mode)
Maximum line length within one network segment:
up to 1200 meters
up to 1200 meters
up to 1200 meters
up to 1200
Galvanic isolation:
• Full. The interface is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Full. The input is isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
Installation type:
Shield
Shield
Shield
Shield
Case size (HxWxD):
96х96х186 mm
96х96х186 mm
96х96х186 mm
96х96х186 mm
Installation depth:
190 mm
190 mm
190 mm
190 mm
Weight, not more than:
1.0 kg
1.0 kg
1.0 kg
1.0 kg
Degree of protection:
IP30
IP30
IP30
IP30
Supply voltage:
• Alternating current: ~ 230 (+22 V, -33 V) (50 ± 1) Hz
• Direct current: 24±4 V
• Alternating current: ~ 230 (+22 V, -33 V) (50 ± 1) Hz
• Direct current: 24±4 V
• Alternating current: ~ 230 (+22 V, -33 V) (50 ± 1) Hz
• Direct current: 24±4 V
• Alternating current: ~ 230 (+22 V, -33 V) (50 ± 1) Hz
• Direct current: 24±4 V
Power consumption:
• Alternating current: 13 VA
• Direct current: no more than 350 mA
• Alternating current: 13 VA
• Direct current: no more than 350 mA
• Alternating current: 13 VA
• Direct current: no more than 350 mA
• Alternating current: 13 VA
• Direct current: no more than 350 mA
Ambient temperature:
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C
Premises of use:
closed explosion-proof, fire-proof
closed explosion-proof, fire-proof
closed explosion-proof, fire-proof
closed explosion-proof, fire-proof
Vibration:
with a frequency of up to 60 Hz with an amplitude of up to 0.1 mm
with a frequency of up to 60 Hz with an amplitude of up to 0.1 mm
with a frequency of up to 60 Hz with an amplitude of up to 0.1 mm
with a frequency of up to 60 Hz with an amplitude of up to 0.1 mm
Atmospheric pressure:
from 84 to 106.7 kPa
from 84 to 106.7 kPa
from 84 to 106.7 kPa
from 84 to 106.7 kPa