Touch operator panels Weintek
I/O modules
Spark protection barrier
Recorders and archivers
Meters and converters of electrical network parameters
Counters, timers, tachometers
Liquid level indicators and regulators
Programmed logical controllers
Manual signal transmitters
Technological signaling devices
Power supplies
Codesys PLC controllers
Galvanic isolation and branching blocks
Communication interface converters and amplifiers
Analytical instruments
Switching blocks
Control and protection units
GSM communication routers / modems
- AC current converter
ПНС-3
ПНС-3
ПНС-653
ПНС-420
Type of power supply:
Single-phase
Single-phase
Single-phase
Single-phase
Input signal type:
AC current
AC current
AC current
DC current
Quantity inputs:
1
1
1
1
Ranges of possible input signals:
From 0 to 1 A
From 0 to 2.5 A
From 0 to 5 A
From 0 to 1 A
From 0 to 2.5 A
From 0 to 5 A
From 0 to 5 A
From 0 to 1 A
From 0 to 2.5 А
From 0 to 5 A
Limit of the basic combined measurement error:
0,25 %
0,4 %
0,25 %
0,4 %
Measurement and conversion period:
adjustable time: 0.5–6 seconds
adjustable time: 0.5–6 seconds
no more 1 seconds
Configurable: max 0.6 seconds
Ultimate load:
Repeated twice, duration up to 5 seconds
Repeated twice, duration up to 5 seconds
overcurrent up to 100 A for a duration of up to 100 milliseconds
an overcurrent of 5 times the nominal value for up to 5 seconds
Maximum input signal frequency:
80 kHz
-
-
-
Number of outputs:
1
1
1
1
Output type:
Active output
Active output
Active output
passive output
Ranges of possible output signals:
0 to 5 mA / R ≤ 2000 Ω
–5 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
–10 to 10 V / R ≤ 2 кΩ
0 to 5 mA / R ≤ 2000 Ω
–5 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
–10 to 10 V / R ≤ 2 кΩ
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 10 V / R ≤ 2 кΩ
4 to 20 mA / R ≤ 500 Ω
Digital display:
Not included
Not included
Not included
Not included
Supply voltage:
Direct current: 24 V
Alternating current: 230 V
Direct current: 24 V
Alternating current: 230 V
Direct current: 24 V
Direct current: 24 V (current loop)
Power consumption:
Direct current: no more than 120 mА
Alternating current: ≤ 5.0 VА
Direct current: no more than 100 mА
Alternating current: ≤ 5.0 VА
Direct current: no more than 30 mА
Direct current: no more than 30 mА
Galvanic isolation:
• Complete. All nodes are isolated from each other
• Galvanic (electrical) isolation voltage not less than 2000 V
• Complete. All nodes are isolated from each other
• Galvanic (electrical) isolation voltage not less than 2000 V
• Complete. All nodes are isolated from each other
• Galvanic (electrical) isolation voltage not less than 2000 V
-
Installation type:
for DIN rail mounting
for DIN rail mounting
for DIN rail mounting
for DIN rail mounting
Weight, not more than:
not more than 0.5 kg
not more than 0.2 kg
not more than 0.1 kg
not more than 0.1 kg
Case size (HxWxD):
95х100х110 mm
100х23х115 mm
94х7х64 mm
76х26х115 mm
Degree of protection:
IP30
IP20
IP20
IP20
Ambient temperature:
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C