Touch operator panels Weintek
Controllers (PID, ON/OFF)
I/O modules
Spark protection barrier
Recorders and archivers
Meters and converters of electrical network parameters
Counters, timers, tachometers
Liquid level indicators and regulators
Programmed logical controllers
Manual signal transmitters
Technological signaling devices
Power supplies
Codesys PLC controllers
Normalizing converters
Galvanic isolation and branching blocks
Communication interface converters and amplifiers
Analytical instruments
Switching blocks
Control and protection units
GSM communication routers / modems
ІТМ-10
ІТМ-11
ІТМ-11В
Device type:
Technological indicator
Technological indicator
Technological indicator
Additional features:
Input signal conversion
Alarms
Input signal conversion
Alarms
Input signal conversion
Alarms
Quantity of analog inputs:
1
1
1
Types of input sensors and signals:
0-5 mA, 0-20 mA, 4-20 mA
0-75 mВ , 0-200 mВ , 0-2 V, 0-10 V
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100
Type: K,L,J,S,B,E,A-1
0-5 mA, 0-20 mA, 4-20 mA
0-75 mВ , 0-200 mВ , 0-2 V, 0-10 V
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100
Type: K,L,J,S,B,E,A-1
0-5 mA, 0-20 mA, 4-20 mA
0-75 mВ , 0-200 mВ , 0-2 V, 0-10 V
Cu 50, Cu 100, Pt 50P, Pt 100P, Pt50, Pt100
Type: K,L,J,S,B,E,A-1
Limit of the basic combined measurement error:
≤ 0.2 %
≤ 0.2 %
≤ 0.2 %
Рolling cycle time:
up to 0.1 seconds
up to 0.1 seconds
up to 0.1 seconds
Galvanic isolation:
• Input isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Input isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
• Input isolated from other circuits.
• Galvanic isolation voltage is not less than 500 V.
Switching to another sensor type:
User-configurable, calibration required
User-configurable, calibration required
User-configurable, calibration required
Quantity of discrete inputs:
Not included
Not included
Not included
Number of outputs:
1
1
1
Output type:
active
active
active
Ranges of possible output signals:
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
0 to 5 mA / R ≤ 2000 Ω
0 to 20 mA / R ≤ 500 Ω
4 to 20 mA / R ≤ 500 Ω
The limit of the main combined error of the output signal formation:
≤ 0.2 %
≤ 0.2 %
≤ 0.2 %
Quantity of discrete outputs:
2
2
2
Types of discrete outputs:
• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• Solid State Relay (SSR): up to 60 V, 1 A
• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• Solid State Relay (SSR): up to 60 V, 1 A
• NPN transistor: up to 40V, 100mA
• Switching relay: up to 230V, 8A
• Solid State Relay (SSR): up to 60 V, 1 A
Data exchange interface:
RS-485
RS-485
RS-485
Data exchange protocol:
Modbus RTU
Modbus RTU
Modbus RTU
Indication type:
Seven-segment, digital
Seven-segment, digital
Seven-segment, digital
Linear indicator, bar graph
Indication accuracy:
Four categories
Four categories
Linear indicator, bar graph
Four categories
Supply voltage:
Direct current: 24 V
Direct current: 24 V
Direct current: 24 V
Power consumption:
Direct current: no more than 150 mA
Direct current: no more than 200 mA
Direct current: no more than 200 mA
Availability of a built-in power supply for inputs:
Not included
Not included
Not included
Non-volatile memory:
Yes, EEPROM
Yes, EEPROM
Yes, EEPROM
Galvanic isolation:
• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 1500 V
• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 1500 V
• Full. All components of the device are isolated from each other.
• Galvanic (electrical) isolation voltage (for outputs and interface), not less than 1500 V
Installation type:
Shield
Shield
Shield
Case size (HxWxD):
48х96х170 mm
48х96х170 mm
96х48х170 mm
Weight, not more than:
не більше 0,35 kg
не більше 0,35 kg
не більше 0,35 kg
Degree of protection:
IP30
IP30
IP30
Ambient temperature:
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C