Home Normalizing converters Pneumatic:

- Pneumatic-electric converter

PEP-11 - Pneumatic-electric converter

Choose a modification:

Order code:

PEP-11
AA
Input signal range:
СС
Output signal type:
PP
Type of measuring pressure:
TT
Size of the tube to be connected:
U
Supply voltage:

Number:

Available for order.

Pneumatic-electric signal conversion unit, with galvanic isolation:

  • Designed for continuous proportional signal conversion: excess pressure of compressed air coming from pneumatic devices of pressure, vacuum, pressure difference, liquid level and density, into unified current signals 4...20 mA, 0...20 mA, 0...5 mA and voltage 0...10 V.
  • Input signal measurement range: 0 - 10 kPa; 0 - 50 kPa; 0 - 100 kPa; 20 - 100 kPa; 0 - 200 kPa.
  • Power supply: ~(220±22)V, = 24 V, 50 mA.
  • Screw terminal block.
Inputs:
  • quantity: 1
  • 0-10kPa, 0-50kPa, 0-100kPa, 20-100kPa, 0-200kPa.
Inlet pressure type:
  • absolute
  • relative
  • differential.
Outputs:
  • quantity: 1
  • active
  • 0-5mA, 0(4)-20mA, 0-10V.
Seller

from

11 142

including VAT

Choose a modification and complete your order code

PEP-11

PEP-420

PEP-420

Input signals:

Quantity inputs:

1

1

1

Input type:

Absolute pressure
Gage pressure
Differential pressure

Differential pressure

Absolute pressure
Differential pressure

Ranges of possible input signals:

0 - 10 kPа
0 - 50 kPa
0 - 100 kPa
20 - 100 kPa
0 - 200 kPa

0 - 10 kPа
0 - 50 kPa
0 - 100 kPa
20 - 100 kPa
0 - 200 kPa

0 - 10 kPа
0 - 50 kPa
0 - 100 kPa
20 - 100 kPa
0 - 200 kPa

Limit of the basic combined measurement error:

0-10 kPа: ±1,0 %
0-50 kPа: ±0,5 %
0-200 kPа: ±0,5 %
0-100 kPa ±0,25 %
20-100 kPa ±0,25 %

0-10 kPа: ±1,0 %
0-50 kPа: ±0,5 %
0-200 kPа: ±0,5 %
0-100 kPa ±0,25 %
20-100 kPa ±0,25 %

0-10 kPа: ±1,0 %
0-50 kPа: ±0,5 %
0-200 kPа: ±0,5 %
0-100 kPa ±0,25 %
20-100 kPa ±0,25 %

Measurement and conversion period:

0,01 second

0,01 second

0,01 second

Analog output signals:

Number of outputs:

1

1

1

Output type:

active

passive, current loop

passive, current loop

Ranges of possible output signals:

0 to 5 mA / R = 2000 Ohm
0 to 20 mA / R ≤ 500 Ohm
4 to 20 mA / R ≤ 500 Ohm
0 to 10 V / R ≥ 2000 Ohm

4 to 20 mA / R ≤ 500 Ohm

4 to 20 mA / R ≤ 500 Ohm

Discrete output signals:

Availability of discrete outputs:

No

No

No

Quantity of discrete outputs:

not included

not included

not included

Types of discrete outputs:

not included

not included

not included

Interfaces:

Data exchange interface:

not included

not included

not included

Data exchange protocol:

not included

not included

not included

Indication:

Digital display:

No

No

No

Electrical data:

Supply voltage:

Direct current: 24 V
Alternating current: 230 V

Current loop, 24V

Current loop, 24V

Power consumption:

Direct current: no more than 120 mA
Alternating current: no more than 5 VA

no more than 20 mA (channel)

no more than 20 mA (channel)

Non-volatile memory:

not included

not included

not included

Galvanic isolation:

• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 500 V.

• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 500 V.

• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 500 V.

Corps:

Installation type:

on DIN rail

on DIN rail

on DIN rail

Case size (HxWxD):

96х55х110 mm

76х26х115 mm

76х26х115 mm

Weight, not more than:

0,4 kg

0,2 kg

0,2 kg

Degree of protection:

IP30

IP30

IP30

Operating conditions:

Ambient temperature:

-40 °C to +70 °C

-40 °C to +70 °C