Touch operator panels Weintek
I/O modules
Spark protection barrier
Recorders and archivers
Meters and converters of electrical network parameters
Counters, timers, tachometers
Liquid level indicators and regulators
Programmed logical controllers
Manual signal transmitters
Technological signaling devices
Power supplies
Codesys PLC controllers
Galvanic isolation and branching blocks
Communication interface converters and amplifiers
Analytical instruments
Switching blocks
Control and protection units
GSM communication routers / modems
PEP-11
PEP-420
PEP-420
Quantity inputs:
1
1
1
Input type:
Absolute pressure
Gage pressure
Differential pressure
Differential pressure
Absolute pressure
Differential pressure
Ranges of possible input signals:
0 - 10 kPа
0 - 50 kPa
0 - 100 kPa
20 - 100 kPa
0 - 200 kPa
0 - 10 kPа
0 - 50 kPa
0 - 100 kPa
20 - 100 kPa
0 - 200 kPa
0 - 10 kPа
0 - 50 kPa
0 - 100 kPa
20 - 100 kPa
0 - 200 kPa
Limit of the basic combined measurement error:
0-10 kPа: ±1,0 %
0-50 kPа: ±0,5 %
0-200 kPа: ±0,5 %
0-100 kPa ±0,25 %
20-100 kPa ±0,25 %
0-10 kPа: ±1,0 %
0-50 kPа: ±0,5 %
0-200 kPа: ±0,5 %
0-100 kPa ±0,25 %
20-100 kPa ±0,25 %
0-10 kPа: ±1,0 %
0-50 kPа: ±0,5 %
0-200 kPа: ±0,5 %
0-100 kPa ±0,25 %
20-100 kPa ±0,25 %
Measurement and conversion period:
0,01 second
0,01 second
0,01 second
Number of outputs:
1
1
1
Output type:
active
passive, current loop
passive, current loop
Ranges of possible output signals:
0 to 5 mA / R = 2000 Ohm
0 to 20 mA / R ≤ 500 Ohm
4 to 20 mA / R ≤ 500 Ohm
0 to 10 V / R ≥ 2000 Ohm
4 to 20 mA / R ≤ 500 Ohm
4 to 20 mA / R ≤ 500 Ohm
Availability of discrete outputs:
No
No
No
Quantity of discrete outputs:
not included
not included
not included
Types of discrete outputs:
not included
not included
not included
Data exchange interface:
not included
not included
not included
Data exchange protocol:
not included
not included
not included
Digital display:
No
No
No
Supply voltage:
Direct current: 24 V
Alternating current: 230 V
Current loop, 24V
Current loop, 24V
Power consumption:
Direct current: no more than 120 mA
Alternating current: no more than 5 VA
no more than 20 mA (channel)
no more than 20 mA (channel)
Non-volatile memory:
not included
not included
not included
Galvanic isolation:
• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 500 V.
• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 500 V.
• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 500 V.
Installation type:
on DIN rail
on DIN rail
on DIN rail
Case size (HxWxD):
96х55х110 mm
76х26х115 mm
76х26х115 mm
Weight, not more than:
0,4 kg
0,2 kg
0,2 kg
Degree of protection:
IP30
IP30
IP30
Ambient temperature:
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C