- Interface conversion block RS-485/Ethernet
BPI-52
BPI-54
BPI-452
SDS-485
Operating modes:
RealCOM - virtual COM port
RealCOM - virtual COM port
RealCOM - virtual COM port
RealCOM - virtual COM port
TCP Client
TCP Server
Interface type 1:
USB
USB
USB
Ethernet, RJ-45
Maximum data transfer rate:
12 Mbps
12 Mbps
12 Mbps
10/100 Mbps
Maximum length of communication line, m:
3
3
3
40
Maximum number of devices, pcs:
1
1
1
1
Interface type 2:
RS-485
RS-422/RS-423
RS-485
4xRS-485
RS-485
RS-485
Maximum data transfer rate:
up to 115200 bps
RS-422, RS-422A: 10000 kbit/s
RS-423: 100 kbit/s
RS-485: up to 115200 bps
Each RS-485: up to 115200 bps
up to 230400 bps
Maximum length of communication line, m:
up to 1200m, at a speed of 9600 bps
RS-422, RS-422A: up to 1200m, at a speed of 90 kbit/s
RS-423: up to 1200m, at a speed of 1 kbit/s
RS-485: up to 1200m, at a speed of 9600 bps
Each RS-485: up to 1200m, at a speed of 9600 bps
up to 1200m, at a speed of 9600 bps
Maximum number of devices, pcs:
up to 32
up to 32
Each RS-485: up to 32
up to 32
Line type:
two-wire
four-wire
two-wire
two-wire
Supply voltage:
from USB
from USB
from USB
Direct current: 24 V
Alternating current: no more than 5VA
Power consumption:
no more than 65 mA
no more than 65 mA
no more than 150 mA
Direct current: no more than 65 mA
Alternating current: no more than 2VA
Galvanic isolation:
• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 500 V.
• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 500 V.
• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 500 V.
• Full. All components of the device are isolated from each other.
• Galvanic isolation voltage is not less than 500 V.
Installation type:
on DIN rail
on DIN rail
on DIN rail
on DIN rail
Case size (HxWxD):
76х26х115 mm
76х26х115 mm
76х26х115 mm
76х26х115 mm
Weight, not more than:
0,13 kg
0,13 kg
0,13 kg
0,13 kg
Degree of protection:
IP30
IP30
IP30
IP30
Ambient temperature:
-40 °C to +70 °C
IP30
-40 °C to +70 °C
-40 °C to +70 °C
-40 °C to +70 °C